Specification Action
Reduced voltage Starter
Reduced voltage Starter

Without enclosure (no CT): SDO-P100 Without enclosure (with CT): SDO-P100T Enclosure (no ammeter): SDE-P100 Enclosure (with ammeter): SDA-P100

More
Reduced voltage Starter
Reduced voltage Starter

Without enclosure (no CT): SDO-P125 Without enclosure (with CT): SDO-P125T Enclosure (no ammeter): SDE-P125 Enclosure (with ammeter): SDA-P125

More
Reduced voltage Starter
Reduced voltage Starter

Without enclosure (no CT): SDO-P150 Without enclosure (with CT): SDO-P150T Enclosure (no ammeter): SDE-P150 Enclosure (with ammeter): SDA-P150

More
Reduced voltage Starter
Reduced voltage Starter

Without enclosure (no CT): SDO-P220 Without enclosure (with CT): SDO-P220T Enclosure (no ammeter): SDE-P220 Enclosure (with ammeter): SDA-P220

More
Push button
Push button

Function: ON | OFF Weight: 72.5g

More
Push button
Push button

Function: FWD│REV│OFF Weight: 110g

More
Auxiliary Contact Block
Auxiliary Contact Block

Type: AP-20 / AP-11 / AP-02 Contacts: 2NO / 1NO 1NC / 2NC Applicable contactor: SR-P40, SR-P50, S-P11~S-P80T, SD-P11~SD-P21

More
Auxiliary Contact Block
Auxiliary Contact Block

Type: AP-40 / AP-31 / AP-22 Contacts: 4NO / 3NO 1NC / 2NO 2NC Applicable contactor: SR-P40, SR-P50, S-P11~S-P80T, SD-P11~SD-P21

More
Auxiliary Contact Block
Auxiliary Contact Block

Type: APS-11 / APL-11 Contacts: 1NO 1NC / 1NO 1NC Applicable contactor: APS-11: SR-P40, SR-P50, S-P11~S-P60T, SD-P11~SD-P21 APL-11: S-P125, S-P150T, S-P200T, S-P220T, S-P300T, S-P400T

More
Modular Contactor
Modular Contactor

Rated Current: 16, 25, 40, 63A Rated Operational Voltage (Ue): 2P: AC230V / 4P: AC400V Rated impulse withstand voltage: 40,000V Contacts: 1NO1NC, 2NO, 2NC, 2NO2NC, 1NO3NC, 3NO1NC, 4NO, 4NC

More
Modular Contactor - Accessory
Modular Contactor - Accessory

Contacts: 1NO1NC Voltage: 500V

More
Modular Contactor - Accessory
Modular Contactor - Accessory

Dimension: 9mm

More
Surge Protective Device
Surge Protective Device

Din rail installation Class II Max. discharge current Imax/Iimp: 20kA (8/20μs) Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N Uc(AC): 320V In(8/20μs): 10kA

More
Surge Protective Device
Surge Protective Device

Din rail installation Class II Max. discharge current Imax/Iimp: 40kA (8/20μs) Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N Uc(AC): 385V In(8/20μs): 20kA

More
Surge Protective Device
Surge Protective Device

Din rail installation Class II Max. discharge current Imax/Iimp: 80kA (8/20μs) Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N Uc(AC): 385V In(8/20μs): 40kA

More
Surge Protective Device
Surge Protective Device

Din rail installation Class II Max. discharge current Imax/Iimp: 100kA (8/20μs) Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N Uc(AC): 385V In(8/20μs): 60kA

More
Surge Protective Device
Surge Protective Device

Din rail installation Class I Max. discharge current Imax/Iimp: 40kA (8/20μs) Pole: 1P / 1P+1 / 1P+N / 3P / 3P+1 / 3P+N Uc(AC): 440V In(10/350μs): 25kA

More
Surge Protective Device Counter
Surge Protective Device Counter

Rated operation voltage: 85~250V Counter pulse threshold: ≧ 1kA Maximum count: 99 Counting method: Pulse Counter display method: 2 digits LED red Minimum interval between counter pulses: ≧ 200ms Digital memory method: Pulse falling edge, flash accumulation record Dimension: 91 x 68 x 18 (mm)

More
Automatic Transfer Switch
Automatic Transfer Switch

Standard: IEC60947-2 Frame size (AF): 100, 125, 250, 400, 630, 800, 1000, 1200, 1600 Poles: 2P / 3P / 4P Rated Current (A): 2P Up to 400A, 3P Up to 1600A, 4P Up to 800A

More
Automatic Transfer Switch
Automatic Transfer Switch

Standard: IEC60947-2 Rated current: 6, 10, 15, 16, 20A Pole: 1P / 2P

More
ATS Disk Controller
ATS Disk Controller

TDNE : Adjustable 1 ~ 30 sec (Time delay of transfer from normal to emergency) TDEN : Adjustable 1 ~ 30 sec (Time delay of transfer from emergency to normal) TDEC : Adjustable 1 ~ 3 Min (Time delay for engine cool-off) TDES : built-in fixed 2 sec (Time delay on engine starting)

More
Miniature Circuit Breaker
Miniature Circuit Breaker

Bolt on type Standard: IEC60947-2 Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A Pole: 1P / 2P / 3P Trip Unit: Thermal magnetic

More
Miniature Circuit Breaker
Miniature Circuit Breaker

Bolt on type Standard: IEC60947-2 Rated current: 15, 20, 30, 40, 50, 60, 75, 100A Pole: 1P / 2P / 3P Trip Unit: Thermal magnetic

More
Miniature Circuit Breaker
Miniature Circuit Breaker

Bolt on type Standard: IEC60947-2 Rated current: 15, 20, 30, 40, 50, 60, 75, 100A Pole: 1P / 2P / 3P Trip Unit: Thermal magnetic

More

Result 145 - 168 of 262

Menu

Best Sale

Made in Taiwan MCCB Circuit Breaker System Manufacturer | Shihlin Electric

Located in Taiwan since 1955, Shihlin Electric & Engineering Corp. has been a breaker switchgear and circuit breaker system manufacturer. Their main products, include circuit breakers, magnetic switchs, power distribution systems and magnetic contactors, which are sold to world-class clients such as TSMC, GE, Mitsubishi Electric, Eaton and so forth.

Established in 1955, SHIHLIN ELECTRIC & ENGINEERING CORPORATION has expanded its operations from basic construction to public works, from the development of electrical power resources to assisting in industry upgrade for Low Voltage Electrical Beaker Switchgear and Circuit Breaker System. With more than 60 years International business in Low Voltage power distribution and motor control experience, Shihlin Electric is specialized in Low Voltage Electrical Beaker Switchgear and Circuit Breaker System.

Shihlin Electric has been offering clients low-voltage electrical switchgear and MCCB circuit breaker systems, both with advanced technology and 68 years of power distribution experience, Shihlin Electric ensures each customer's needs are met.

Hot Products